Firefighting is the act of extinguishing destructive fires. A firefighter fights these fires and prevents destruction of life, property and the environment. Firefighting is a highly technical profession which requires years of training and education to become proficient in.

Historically, physicists created a graphical representation detailing the three elements of fire (fire triangle). In recent years, one more point has been added, creating the fire tetrahedron.

The four elements needed to sustain combustion are:

To extinguish a fire, it is necessary to remove one or more of the four components of combustion. Removing any of these components of the fire tetrahedron will stop the other elements from interacting and not allow combustion to continue. Firefighters work on limiting exposures (fuel that is in jeopardy of being ignited by nearby flame or from radiant heat), containing and extinguishing fire and then overhauling charred and burned debris from the affected areas as well as extinguishing all hidden fires to prevent a rekindle.

Firefighters' goals are to save life, property and the environment. A fire can rapidly spread and endanger many lives; however, with modern firefighting techniques, catastrophe is usually avoided. To prevent fires from starting, a firefighter's duties include public education and conducting fire inspections. Because firefighters are often the first responders to people in critical conditions, firefighters provide basic life support as emergency medical technicians or advanced life support as licensed paramedics.


Contents

Risks of a fire

Fire fighting:Firefighters arrive at the scene.
Enlarge
Firefighters arrive at the scene.
Fire fighting:A burning building casts off clouds of smoke.
Enlarge
A burning building casts off clouds of smoke.

The primary risk to people in a fire is smoke inhalation (breathing in smoke); most of those killed in fires die from this, not from burns. The risks of smoke include :

As an example, plastics inside a car can generate 200,000 m3 of smoke at a rate of 20-30 m3/sec.[citation needed]. Firefighters carry self-contained breathing apparatus (SCBA) (a closed-circuit positive pressure compressed air system) to prevent smoke inhalation.

Obvious risks stem from the effects of heat. Even without contact with the flames (conduction), there are a number of comparably serious risks: burns from radiated heat, contact with a hot object, hot gases (e.g., air), steam and hot and/or toxic smoke. Firefighters are equipped with personal protective equipment (PPE) that includes fire-resistant clothing (nomex or polybenzimidazole fiber (PBI)) and helmets that limit the transmission of heat towards the body.

The heat can make pressurised gas cylinders and tanks explode, producing what is called a BLEVE (Boiling Liquid Expanding Vapor Explosion). Some chemical products such as ammonium nitrate fertilizers can also explode. Explosions can cause physical trauma or potentially serious blast or shrapnel injuries.

Heat causes human flesh to burn as fuel causing severe medical problems. Depending upon the heat of the fire, burns can occur in a fraction of a second. A first degree burn (on the skin surface) is extremely painful. A second degree burn is a burn into the skin, and can cause shock, infections, and dehydration and if left untreated often results in death. Second degree burns comprimise nerve tissue and are not painful. Third degree burns leave muscles and internal organs exposed from completely destroyed skin. If the person survives the shock and exposure to germs, medical treatment is extremely difficult.

Additional risks of firefighting encompass the following:

Reconnaissance and reading the fire

The first step of the operations is a reconnaissance to search for the origin of the fire (which may not be obvious for an indoor fire, especially when there are no witnesses), and spot the specific risks and the possible casualties. Any fire occurring outside may not require reconnaissance; on the other hand, a fire in a cellar or an underground car park with only a few centimeters of visibility may require a long reconnaissance to spot the seat of the fire.

The "reading" of the fire is the analysis by the firefighters of the forewarnings of a thermal accident (flashover, backdraft, smoke explosion), which is performed during the reconnaissance and the fire suppression maneuvers. The main signs are:

Suppressing the fuel and the energy

The first method is to remove fuel for the fire by, for example, cutting off the domestic gas supply and moving combustible objects from the path of the fire. When the activation energy is still present, it is also useful to switch it off; this will not stop a fire, but will help in controlling a starting fire and will prevent a new fire from occurring.

Important

The first action is thus to "cut off the energies", such as domestic gas and electricity, and switch off working machines (motors). It is also important to turn off ventilation and air conditioning, as they supply oxygen which supports combustion and can dangerously change the behaviour of the fire.

Use of water

Often, the main way to extinguish a fire is to spray with water. The water has two roles:

The extinction is thus a combination of "asphyxia" and cooling. The flame itself is suppressed by asphyxia, but the cooling is the most important element to master a fire in a closed area.

Open air fire

For fires in the open, the seat of the fire is sprayed with a straight spray: the cooling effect immediately follows the "asphyxia" by vapor, and reduces the amount of water required. A straight spray is used so the water arrives massively to the seat without being vaporized before. A strong spray may also have a mechanical effect: it can disperse the combustible product and thus prevent the fire from starting again.

The fire is always fed with air, but the risk to people is limited as they can move away, except in the case of wildfires or bushfires where they can be surrounded by the flames. But there might be a big risk of expansion.

Spray is aimed at a surface, or object: for this reason, the strategy is sometimes called two-dimensional attack or 2D attack.

It might be necessary to protect specific items (house, gas tank) against infrared radiation, and thus to use a diffused spray between the fire and the object.

Breathing apparatus is often required as there is still the risk of breathing in smoke or poisonous gases.

Closed volume fire

Until the 1970s, fires were usually attacked while they declined, so the same strategy as for open air fires was effective. In recent times, fires are now attacked in their development phase as:

Additionally, in these conditions, there is a greater risk of backdraft and of flashover.

Spraying of the seat of the fire directly can have unfortunate and dramatic consequences: the water pushes air in front of it, so the fire is suppled with extra oxygen before the water reaches it. This activation of the fire, and the mixing of the gases produced by the water flow, can create a flashover.

The most important issue is not the flames, but control of the fire, i.e. the cooling of the smoke that can spread and start distant fires, and that endanger the life of people, including firefighters. The volume must be cooled before the seat is treated. This strategy originally of Swedish (Mats Rosander & Krister Giselsson) origin, was further adapted by London Fire Officer Paul Grimwood following a decade of operational use in London's busy west-end district between 1984-94 (www.firetactics.com) and termed three-dimensional attack, or 3D attack.

Use of a diffused spray was first proposed by Chief Lloyd Layman of Parkersburg, West Virginia Fire Department, at the Fire Department Instructor's Conference (FDIC) in 1950 held in Memphis, Tennessee, U.S.A.

Using Grimwood's modified '3D attack strategy' the ceiling is first sprayed with short pulses of a diffused spray:

Only short pulses of water must be sprayed, otherwise the spraying modifies the equilibrium, and the gases mix instead of remaining stratified: the hot gases (initially at the ceiling) move around the room and the temperature rises at the ground, which is dangerous for firefighters. An alternative is to cool all the atmosphere by spraying the whole atmosphere as if drawing letters in the air ("pencilling").

The modern methods for an urban fire dictate the use of a massive initial water flow, e.g. 500 L/min for each fire hose. The aim is to absorb as much heat as possible at the beginning to stop the expansion of the sinister, and to reduce the smoke. When the flow is too small, the cooling is not sufficient, and the steam that is produced can burn firefighters (the drop of pressure is too small and the vapor is pushed back). Although it may seem paradoxical, the use of a strong flow with an efficient fire hose and an efficient strategy (diffused sprayed, small droplets) requires a smaller amount of water: once the temperature is lowered, only a limited amount of water is necessary to suppress the fire seat with a straight spray. For a living room of 50 m² (60 square yards), the required amount of water is estimated as 60 L (15 gallons).

French fire-fighters used an alternative method in the 1970s: they sprayed water on the hot walls to create a water vapour atmosphere and asphyxiate the fire. This method is no longer used because it was risky: the pressure created pushed the hot gases and vapour towards the firefighters, causing severe burns, and pushed the hot gases into other rooms where they could start a new fire.

Asphyxiating a fire

In some cases, the use of water is undesirable:

It is then necessary to asphyxiate the fire. This can be done in two ways:

Tactical Ventilation or isolation of the fire

One of the main risks of a fire is the smoke: it carries heat and poisonous gases, and obscures vision. In the case of a fire in a closed location (building), two different strategies may be used: isolation of the fire, or positive pressure ventilation.

Paul Grimwood introduced the concept of tactical ventilation in the 1980s to encourage a more well thought out approach to this aspect of firefighting. Following work with Warrington Fire Research Consultants (FRDG 6/94) his terminology and concepts were adopted officially by the UK fire service and are now referred to throughout revised Home Office training manuals (1996-97).

Paul Grimwood's original definition of his 1991 unified strategy stated that ....

'tactical ventilation is either the venting, or containment (isolation) actions by on-scene firefighters, used to take control from the outset of a fire's burning regime, in an effort to gain tactical advantage during interior structural firefighting operations'.

Positive pressure ventilation (PPV) consists of using a fan to create excess pressure in a part of the building; this pressure will push the smoke and the heat away, and thus secure the rescue and fire fighting operations. It is necessary to have an exit for the smoke, to know the building very well to predict where the smoke will go, and to ensure that the doors remain open by wedging or propping them. The main risk of this method is that it may activate the fire, or even create a flashover, e.g. if the smoke and the heat accumulate in a dead end.

Before the fire brigade arrives

Firefighters should be called when there is any possibility that the fire cannot be contolled within a few seconds, because fires can grow exponentially quickly: A fire at its beginning is easy to extinguish: a wisp of breath or a drop of water can extinguish a match. A bucket of water can extinguish a fire created by a match near a cool-burning fuel source such as cloth or wood after a minute; but after only a few minutes, tons of water or very advanced methods may be required. It is thus important to know how to fight a starting fire, but also to know that once it has started, the most effective action is to warn people to evacuate the building (if necessary) and call for help; any attempt at controlling the fire beyond the very first sure attempts could be dangerous and harmful if by doing so, evacuation and arrival of firefighters is delayed. Fire fighters respond to a large fraction of calls in which the fire is already controlled when they arrive at the scene; or where there was no fire at all, but only a sign of one. They consider it part of their job to respond to these possible risks, because fires spread exponentially quickly.

The following public education advice is typical for various types of domestic fires (industrial fires require professional knowledge to safely fight):

Consider running from the building. Stay in the building ONLY if there is a good possibility of controlling the fire within a few seconds and avoiding further loss of life or great loss of property. There are cases where not fighting the fire would be more dangerous than fighting it; and there are other cases, where the fire has gotten just out of control, where assistance is critically necessary.

Assess the type of fire, its fuel and combustion sources, its size, and its proximity to people or valuable property. The following guidelines are for various types of house fires:

When the fire cannot be fought, it is necessary to alert occupants and call for help:

During the evacuation, it is important:

As soon as possible it is vital to find out with certainty who was in the building, and who has been evacuated, so that lifesavers know what to do. Evacuated people should stay together to facilitate this.

An evacuation is an emergency, but if handled calmly (where possible) and following public education guidelines, effective escapes can prevent death and injury for the greatest numbers. Exceptions may exist, and a person who stays calm in an emergency and observes the specific situation is sometimes the best judge of what to do. (For example, some people say that there is a rare--and very dangerous, because the shafts can transmit flash fires, smoke, chemicals, and the elevators can get stuck or out of control of its users, and electricity can go out--exception to never using elevators, which maybe could have been used to save some of the victims of 11 September 2001). However, exceptions are not generally noted in public education because people have a tendency to panic and use those ideas at the wrong times excluding much better advice.

Appendix : Calculation of the amount of water required to suppress a fire in a closed volume

In the case of a closed volume, it is easy to compute the amount of water needed. The oxygen (O2) in air (21%) is necessary for combustion. Whatever the amount of fuel available (wood, paper, cloth), combustion will stop when the air becomes "thin", i.e. when it contains less than 15% oxygen. If additional air cannot enter, we can calculate:

These computations are only valid when considering a diffused spray which penetrates the entire volume; this is not possible in the case of a high ceiling: the spray is short and does not reach the upper layers of air. Consequently the computations are not valid for large volumes such as barns or warehouses: a warehouse of 1,000 m² (1,200 square yards) and 10 m high (33 ft) represents 10,000 m3. In practice, such large volumes are unlikely to be airtight anyway.

Volume computation

Fire needs air; if water vapour pushes all the air away, the fuel can no longer burn. But the replacement of all the air by water vapour is harmful for firefighters and other people still in the building: the water vapour can carry much more heat than air at the same temperature (one can be burnt by water vapour at 100 °C (212 °F) above a boiling saucepan, whereas it is possible to put an arm in an oven—without touching the metal!—at 270 °C (520 °F) without damage). This amount of water is thus an upper limit which should not actually be reached.

The optimal, and minimum, amount of water to use is the amount required to dilute the air to 15% oxygen: below this concentration, the fire cannot burn.

The amount used should be between the optimal value and the upper limit. Any additional water would just run on the floor and cause water damage without contributing to fire suppression.

Remember: Most cities use a mix between volunteers and paid firefighters!

Let us call:

then for an air at 500 °C (773 K, 932 °F, best case concerning the volume, probable case at the beginning of the operation), we have1

<math>V_v = 3571 \cdot V_w</math>

and for a temperature of 100 °C (373 K, 212 °F, worst cas concerning the volume, probable case when the fire is suppressed and the temperature is lowered):2

<math>V_v = 1723 \cdot V_w</math>

For the maximum volume, we have:

<math>V_v = V_r</math>

considering a temperature of 100 °C.To compute the optimal volume (dilution of oxygen from 21 to 15%), we have3

<math>V_v = 0.286 \cdot V_r </math>

for a temperature of 500 °C.The table below show some results, for rooms with a height of 2.70 m (8 ft 10 in).

Amount of water required to suppress the fire
volume computation
Area of the room Volume of the room Vr Amount of liquid water Vw
maximum optimal
25 m² (30 yd²) 67.5 m³ 39 L (9.4 gal) 5.4 L (1.3 gal)
50 m² (60 yd²) 135 m³ 78 L (19 gal) 11 L (2.7 gal)
70 m² (84 yd²) 189 m³ 110 L (26 gal) 15 L (3.6 gal)

Note that the formulas give the results in cubic meters; which are multiplied by 1,000 to convert to liters.

Of course, a room is never really closed, gases can go in (fresh air) and out (hot gases and water vapour) so the computations will not be exact.

Notes
Note 1: indeed, the mass of one mole of water is 18 g, a liter (0.001 m³) represents one kilogram i.e. 55.6 moles, and at 500 °C (773 K), 55.6 moles of an ideal gas at atmospheric pressure represents a volume of 3.57 m³.
Note 2: same as above with a temperature of 100 °C (373 K), one liter of liquid water produces 1.723 m³ of vapour
Note 3: we consider that only Vr - Vv of the original room atmosphere remains (Vv has been replaced by water vapour). This atmosphere

See also

Fire fighting
People: Firefighter | Fire Marshal | Fire Master | Firefighter Assist and Search Team | Fire police | Smokejumper | Station Officer | Volunteer fire department
Places: Fire Service College | Fire station | Fire lookout tower
Equipment: Glossary of firefighting equipment | Bunker gear | Fire chief's vehicle | Fire apparatus | Fire horn | Fire station | Fire triangle | Fire-retardant material | Fireman's switch | Heat detector | Nomex | Siren | Smoke detector | Splash suit | Super Scooper | Turnout coat
Terminology: Glossary of firefighting terms | Glossary of wildland fire terms | Dead Man Zone | Draft | Fire classes | Fire control | Fire safety | Fireman's carry | Firewall | Flash fire | Forcible entry | Gaseous fire suppression | Master stream | Stop, drop and roll | Structure fire | Ventilation | Two-in, two-out | Wetdown | Wildfire
Misc: Firefighting worldwide | History of fire brigades | International Association of Fire Fighters | International Firefighters' Day | List of historic fires | London Fire Brigade Museum | National Fire Incident Reporting System | World Police and Fire Games

Categories


Articles with unsourced statements | Articles containing how-to sections | Firefighting

Find

Find

Find